TS7708 series grating spectrophotometer

  • $6,795.00
    • Ex Tax:$6,795.00
    • Brand: 3NH
    • Product Code: TS7708
    • Availability: In Stock
    TS7X series grating spectrophotometer is 3NH company spent 3 years, carefully designed, fully with independent intellectual property rights grating spectrophotometer. The instrument uses 1000 lines of precision shining grating as the optical splitter, built-in silicon photodiode array (double ..

    TS7X series grating spectrophotometer is 3NH company spent 3 years, carefully designed, fully with independent intellectual property rights grating spectrophotometer. The instrument uses 1000 lines of precision shining grating as the optical splitter, built-in silicon photodiode array (double row 40 groups) sensor, imported white board, repeatability delta E* AB easily controlled within 0.03, the use of long life full spectrum LED as the light source, optical resolution in the visible range is less than 10nm.

    Under the condition of d/8 geometric optical illumination recommended by CIE, TS7700 grating spectrophotometer can accurately measure the SCI and SCE reflectance data of samples / fluorescent samples, and also can accurately measure and express various color difference formulas and color indexes in various color spaces. With spectrophotometer TS7700, it can easily realize the accurate transmission of color and can also be used as the detection equipment of accurate color matching system.

    TS7708 spectrometer is equipped with φ 8mm, φ 4mm, 1x3mm three measuring apertures, more adaptability, accurate measurement of color, stable performance, in plastic electronics, paint coating, textile printing and dyeing, printing paper products, automotive, medical, cosmetics and food industries, in scientific research institutions, laboratory fields are widely used.

    Technical Advantages:

    1. Silicon photodiode array (double 40 array) sensor

    The larger area of the double 40 array sensor, the strong light will not saturation, weak light sensitivity and a wider spectrum response range, to ensure the instrument measurement speed, accuracy, stability and consistency, master the core technology, and the international standard of the same platform, complete compatibility.

    11.jpg

    2.  Adopt full waveband balanced LED light source

    The full waveband balanced LED light source ensures sufficient spectral distribution in the visible light range, avoids the spectral loss of white LED in specific waveband, and ensures the measurement speed and accuracy of the measurement results.

    12.png

    3. Grating spectroscopic technique

    Use Grating spectroscopic technique, with higher resolution, to make the color measurement more accurate.

    13.png

    4. Place the base safely to ensure that the whiteboard is not dirty.

    14.jpg

    5. Professional whiteboard, a lifetime never change color commitment

    15.png

    6. Fast charging

    Special fast charging mode, low voltage to remind charging or use off-duty time charging, to ensure the capacity and life of the battery (note: frequent repeated battery charging more harm).

    16.jpg


    7. New fashionable appearance design based on ergonomics

    The position of the hand holding and the measurement button are carefully designed to meet different holding habits, smooth and fine surface, resulting from the high-precision appearance processing art.

    17.jpg

    8. Equipped with three measuring apertures to meet the most samples measurement

    The Factory configuration of spectrophotometer TS7708 is with ø 8mm flat aperture, ø 8mm tip aperture, ø 4mm flat aperture, ø 4mm tip aperture, ø 1x3mm aperture, a total of five measuring apertures, to meet the most samples measurement.

    18.jpg

    9. Camera positioning can clearly observe the measured area

    Spectrophotometer TS7708 built-in camera positioning, through the camera real-time view, can accurately determine whether the object measured part is the target center, improve the measurement efficiency and accuracy.

    19.jpg


    10. Excellent errors between instruments and repeatability

    Ensure the consistency of measurement data of multiple equipment, to be used for color matching and accurate color transfer.

    20.jpg

    11. A variety of color spaces and observation light sources

    Offer CIE LAB,XYZ,Yxy,LCh,CIE LUV, S-RGB,HunterLab,βXY,DIN Lab99 Munsell(C/2) color spaces, and D65, A, C, D50, D55, D75, F1, F2 (CWF), F3, F4 and F5, F6 and F7 (DLF), F8, F9, F10 (TPL5), and F11 (TL84), F12 (TL83 / U30) a variety of light sources, to meet the special measurement requirements under different measurement conditions.

    21.jpg


    12. Adopt international common use d/8 SCI/SCE Synthesis technology

    Adopt D/8 (SCI/SCE) measurement structure to more objectively reflect the color itself, and reduce the impact of object surface texture on test results, in accordance with CIE No.15. GB/T 3978,GB 2893,GB/T 18833,ISO7724-1,ASTM E1164,DIN5033 Teil7.

    22.png

    13. Dual optical path system for more accurate color measurement

    Dual optical path system, optical resolution is less than 10nm in the visible range, can simultaneously measure the sample SCI, SCE spectrum.

    23.jpg

    14. PC software has powerful function expansion

    SQCX quality management software with TS7708 spectrophotometer is suitable for quality monitoring and color data management of various industries. Digitize user data color management.

    24.jpg

    Specification

    Model TS7708
    Optical Geometry D/8 (diffused illumination, 8-degree viewing angle)
    SCI (specular component included)/SCE (specular component excluded) ;
    Include UV / excluded UV light source
    Conforms to CIE No.15, GB/T 3978,GB 2893,GB/T 18833,ISO7724-1,ASTM E1164,DIN5033 Teil7
    Characteristic 3 measuring apertures for accurate color analysis and transmission in laboratory
    It is used for precise color measurement and quality control in plastic electronics, paint and ink, textile and garment printing and dyeing, printing, ceramics and other industries, and for fluorescent sample measurement.
    Integrating Sphere Size Φ40mm
    Light Source Combined full spectrum LED light source, UV light source
    Spectrophotometric Mode Flat Grating
    Sensor Silicon photodiode array (double row 40 groups)
    Wavelength Range 400~700nm
    Wavelength Interval 10nm
    Semiband Width 10nm
    Measured Reflectance Range 0-200%
    Measuring Aperture 3 apertures: MAV:Φ8mm/Φ10mm;SAV:Φ4mm/Φ5mm;LAV:1x3mm
    LAV1x3mm: Slightly poor accuracy, can be used for color test
    Specular Component SCI&SCE
    Color Space CIE LAB,XYZ,Yxy,LCh,CIE LUV,s-RGB,HunterLab,βxy,DIN Lab99 Munsell(C/2))
    Color Difference Formula ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00, DINΔE99,ΔE(Hunter)
    Other Colorimetric Index WI(ASTM E313,CIE/ISO,AATCC,Hunter),
    YI(ASTM D1925,ASTM 313),
    Metamerism Index MI,
    Staining Fastness, Color Fastness, Color Strength, Opacity,
    8° Glossiness,555 tone classification
    Observer Angle 2°/10°
    Illuminant D65,A,C,D50,D55,D75,F1,F2(CWF),F3,F4,F5,F6,F7(DLF),F8,F9,F10(TPL5),F11(TL84),F12(TL83/U30)
    Displayed Data Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Offset
    Measuring Time About 1.5s (Measure SCI & SCE about 3.2s)
    Repeatability Spectral reflectance: MAV/SCI, Standard deviation within 0.08% (400 nm to 700 nm: within 0.18%)
    Chromaticity value: MAV/SCI, within ΔE*ab 0.03 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration)
    Inter-instrument Error MAV/SCI, Within ΔE*ab 0.15
    (Average for 12 BCRA Series II color tiles)
    Measurement Mode Single Measurement, Average Measurement(2-99times)
    Locating Method Camera Locating,stabilizer cross position
    Dimension L*W*H=129X76X217mm
    Weight Approx 600g
    Battery Li-ion battery, 6000 measurements within 8 hours
    Illuminant Life Span 5 years, more than 3 million times measurements
    Displayed Data 3.5-inch TFT color LCD, Capacitive Touch Screen
    Data Port USB, Bluetooth 4.2
    Data Storage Standard 1000 Pcs, Sample 30000 Pcs
    Language Simplified Chinese, English, traditional Chinese
    Operating Environment 0~40℃, 0~85%RH (no condensing), Altitude < 2000m
    Storage Environment -20~50℃, 0~85%RH (no condensing)
    Standard Accessory Power Adapter, User Guide, PC Software(Download from office website), USB cable, White and Black Calibration Cavity, Protective Cover, Wrist strap, 8mm flat aperture, 8mm tip aperture, 4mm flat aperture, 4mm tip aperture,1x3mm tip aperture
    Optional Accessory Micro Printer, Powder Test Box, Holding base
    Notes The specifications are subject to change without notice.

    Write a review

    Please login or register to review